Product Parameters
Parameter Category |
Specific Parameter |
Specification |
Withstand Pressure |
Compound pressure |
500kPa (compound pressure) |
Positive pressure |
1.5MPa (positive pressure) |
|
Vacuum pressure |
500kPa (vacuum pressure) |
|
Rated Pressure Range |
Compound pressure |
-100~100kPa ( compound pressure) |
Positive pressure |
-0.1~1MPa (positive pressure) |
|
Vacuum pressure |
0~-101.0kPa ( vacuum pressure) |
|
Protection Grade |
- |
IP40 |
Set Pressure Range |
Compound pressure |
-103~103kPa ( compound pressure) |
Positive pressure |
-0.103~1.030MPa (positive and negative pressure) |
|
Vacuum pressure |
10.0~-103.0kPa ( vacuum pressure) |
|
Display Refresh Rate |
- |
5 times/second |
RS485 Communication Distance |
- |
Maximum connection distance ≤1200m |
Ambient Temperature |
- |
0~50℃ |
Color |
- |
3 colors (white, red, orange) |
Load Current |
- |
≤200mA |
Humidity |
Action and storage |
35~85% (no water condensation) |
Internal Pressure Drop |
- |
≤1.0V |
Wire Specification |
- |
Oil-resistant PVC cable (0.15mm²) |
Current Consumption |
No load |
≤40mA |
Repeatability Accuracy |
- |
±0.3%F.S ±1digit |
Linearity |
- |
±1%F.S |
Action Indication |
- |
Orange OUT1 |
Weight |
excluding cable |
Approximately 70g |
Applicable Gas |
- |
Air, non-corrosive, non-flammable |
Minimum Unit Scale Value |
Positive pressure type kPa |
kPa(0.001), kgf/cm²(0.01), bar(0.01), psi(0.1) |
Micro and positive-negative pressure type kPa |
kPa(0.1), mmHg(1), kgf/cm²(0.001), bar(0.001), psi(0.01), inHg(0.1) |
|
Vibration Resistance |
Amplitude, frequency, time |
Amplitude 1.5mm, 10Hz~55Hz~10Hz per minute, 2 hours for each of X, Y, Z directions |
Storage Temperature |
Storage |
-10℃~60℃ (without water condensation and freezing) |
Temperature Characteristic |
- |
±3%F.S, reference temperature 25℃ (0~50℃ temperature range) |
Baud Rate |
- |
9600bps, 19200bps, 38400bps, 57600bps, 115200bps |
Insulation Resistance |
Between lead and plastic shell |
≥50MΩ (DC 500V) |
Output Voltage |
Rated voltage |
0.6V~5V ±2.5%F.S (rated voltage) |
Display Accuracy |
- |
±1%F.S ±1digit (temperature 25±3℃) |
Withstand Voltage |
Between lead and plastic shell |
AC 1000V for 1 minute |
Impact Resistance |
- |
100m/s²(10G), 3 times for each of X, Y, Z directions |
Output Type |
- |
Open collector output (NPN or PNP, up to 1 channel output) |
Interface Diameter |
- |
90 degrees inlet port” M5 port” No port |
Response Time |
- |
≤2.5ms (can be set to 25, 100, 250, 500, 1000, 1500ms) |
Design Aesthetics


frequently asked questions
-
What’s the JK92 difference from ordinary pressure switches?
Answer: ① Thin and light (1-3mm thick), attachable to narrow spaces; ② Adhesive-backed installation, time-saving; ③ Membrane sensing, light touch, service life over 1 million times, more durable than mechanical contacts. -
How does it sense pressure, and what can it measure?
-
What about accuracy and protection?
-
What to prepare before installation?
-
How to set pressure upper/lower limits for the first time?
-
What to note in daily use?
-
How to clean and maintain?
-
Switch unresponsive but pressure display normal?
-
Large pressure fluctuation, switch toggles frequently?