JK80 Series Corrosion-resistant pressure sensor Stable with RS485 Communication
Application industry

Pipeline pressure monitoring

Air leak testing

F.R.L (Filter, Regulator, Lubricator)

Gas storage cylinders

Adsorption verification

Air compressors
Product Parameters
Parameter Category |
Specific Parameter |
Specification |
Withstand Pressure |
High pressure |
3.0MPa (high pressure) |
Positive pressure |
1.5MPa (positive pressure) |
|
Compound pressure |
500kPa (compound pressure) |
|
Rated Pressure Range |
High pressure |
0.000~1.999MPa (high pressure) |
Positive pressure |
-0.100~1.000MPa (positive pressure) |
|
Compound pressure |
-100~100kPa (compound pressure) |
|
Protection Grade |
- |
IP65 |
Set Pressure Range |
High pressure |
-0.103~1.999MPa (high pressure) |
Positive and negative pressure |
-0.103~1.030MPa (positive and negative pressure) |
|
Compound pressure |
-103.0~103.0KPa (positive pressure) |
|
Display Refresh Rate |
- |
5 times/second |
RS485 Communication Distance |
- |
Maximum connection distance ≤1200m |
Ambient Temperature |
- |
0~50℃ |
Color |
- |
Red |
Load Current |
- |
≤200mA |
Humidity |
Action and storage |
35~85% (no water condensation) |
Internal Pressure Drop |
- |
≤1.0V |
Wire Specification |
- |
Oil-resistant PVC cable (0.15mm²) |
Current Consumption |
No load |
≤40mA |
Repeatability Accuracy |
- |
±0.3%F.S ±1digit |
Linearity |
- |
±1%F.S |
Action Indication |
- |
OUT1 |
Weight |
|
Approximately148g |
Applicable Gas |
- |
Non-corrosive fluid for SUS316 and FKM |
Minimum Unit Scale Value |
Positive pressure type kPa |
kPa(0.001), kgf/cm²(0.01), bar(0.01), psi(0.1) |
Micro and positive-negative pressure type kPa |
kPa(0.1), mmHg(1), kgf/cm²(0.001), bar(0.001), psi(0.01), inHg(0.1) |
|
Vibration Resistance |
Amplitude, frequency, time |
Amplitude 1.5mm, 10Hz~55Hz~10Hz per minute, 2 hours for each of X, Y, Z directions |
Storage Temperature |
Storage |
-10℃~60℃ (without water condensation and freezing) |
Temperature Characteristic |
- |
±3%F.S, reference temperature 25℃ (0~50℃ temperature range) |
Baud Rate |
- |
9600bps, 19200bps, 38400bps, 57600bps, 115200bps |
Insulation Resistance |
Between lead and plastic shell |
≥50MΩ (DC 500V) |
Output Voltage |
Rated voltage |
0.6V~5V ±2.5%F.S (rated voltage) |
Display Accuracy |
- |
±1%F.S ±1digit (temperature 25±3℃) |
Withstand Voltage |
Between lead and plastic shell |
AC 1000V for 1 minute |
Impact Resistance |
- |
100m/s²(10G), 3 times for each of X, Y, Z directions |
Output Type |
- |
Open collector output (NPN or PNP, up to 2 outputs |
Interface Diameter |
- |
RC1/8” VCR1/4” R1/4” 1/4” |
Response Time |
- |
≤2.5ms (can be set to 25, 100, 250, 500, 1000, 1500ms) |
Design Aesthetics




frequently asked questions
-
Q: What are the requirements for the installation location of the JK80 Series pressure switch?
It is recommended to install it in an area with low vibration and small temperature variation, and keep it away from strong electromagnetic interference sources such as frequency converters and high-power motors. For harsh working conditions (e.g., humid, dusty environments), a vertical installation method (with the pressure connector facing downward) is required, and the inlet point should be sealed to prevent moisture intrusion. When installing or disassembling, use a wrench to turn the hexagonal (or flat square) structure at the connection; do not directly rotate the housing, as this may damage internal components. -
Q: What is the pressure interface specification of the JK80, and how to match the pipeline?
-
Q: How to set the measurement mode?
-
Q: How to restore factory settings?
-
Q: What does it mean when "LLL/HHH" is displayed after power-on?
-
Q: What are the possible reasons if the switch does not actuate when the pressure reaches the set value?
-
Q: What work needs to be done for daily maintenance?
-
Q: What is the product warranty period, and what does the warranty cover?
-
Q: What should be noted when reusing the product after long-term storage?