Product Parameters
Parameter Category |
Specific Parameter |
Specification |
Withstand Pressure |
High pressure |
3.0MPa (high pressure) |
Positive pressure |
2.0MPa (positive pressure) |
|
Compound pressure |
500kPa (compound pressure) |
|
Rated Pressure Range |
High pressure |
0.000~2.000MPa (high pressure) |
Positive pressure |
-0.100~1.000MPa (positive pressure) |
|
Compound pressure |
-100~100kPa (compound pressure) |
|
Protection Grade |
- |
IP65 |
Set Pressure Range |
High pressure |
-0.103~2.030MPa (high pressure) |
Positive and negative pressure |
-0.103~1.030MPa (positive and negative pressure) |
|
Compound pressure |
-103.0~103.0KPa (positive pressure) |
|
Display Refresh Rate |
- |
5 times/second |
RS485 Communication Distance |
- |
Maximum connection distance ≤1200m |
Ambient Temperature |
- |
0~50℃ |
Color |
- |
3 colors (white red orange) |
Load Current |
- |
≤200mA |
Humidity |
Action and storage |
35~85% (no water condensation) |
Internal Pressure Drop |
- |
≤1.0V |
Wire Specification |
- |
Oil-resistant PVC cable (0.15mm²) |
Current Consumption |
No load |
≤40mA |
Repeatability Accuracy |
- |
±0.3%F.S ±1digit |
Linearity |
- |
±1%F.S |
Action Indication |
- |
OUT1 |
Weight |
|
Approximately108g |
Applicable Gas |
- |
Non-corrosive fluid for SUS316 and FKM |
Minimum Unit Scale Value |
Positive pressure type kPa |
kPa(0.001), kgf/cm²(0.01), bar(0.01), psi(0.1) |
Micro and positive-negative pressure type kPa |
kPa(0.1), mmHg(1), kgf/cm²(0.001), bar(0.001), psi(0.01), inHg(0.1) |
|
Vibration Resistance |
Amplitude, frequency, time |
Amplitude 1.5mm, 10Hz~55Hz~10Hz per minute, 2 hours for each of X, Y, Z directions |
Storage Temperature |
Storage |
-10℃~60℃ (without water condensation and freezing) |
Temperature Characteristic |
- |
±3%F.S, reference temperature 25℃ (0~50℃ temperature range) |
Baud Rate |
- |
9600bps, 19200bps, 38400bps, 57600bps, 115200bps |
Insulation Resistance |
Between lead and plastic shell |
≥50MΩ (DC 500V) |
Output Voltage |
Rated voltage |
0.6V~5V ±2.5%F.S (rated voltage) |
Display Accuracy |
- |
±1%F.S ±1digit (temperature 25±3℃) |
Withstand Voltage |
Between lead and plastic shell |
AC 1000V for 1 minute |
Impact Resistance |
- |
100m/s²(10G), 3 times for each of X, Y, Z directions |
Output Type |
- |
Open collector output (NPN or PNP, up to 2 outputs |
Interface Diameter |
- |
RC1/8” VCR1/4” R1/4” M5” |
Response Time |
- |
≤2.5ms (can be set to 25, 100, 250, 500, 1000, 1500ms) |
Design Aesthetics




frequently asked questions
Frequently Asked Questions (FAQ) about Jingkong JK20 Corrosion - Resistant Series
Product Foundation and Material - Related Questions
-
What is the core corrosion - resistant material of the JK20 Corrosion - Resistant Series?
The core components of the product that come into contact with the medium are made of high - quality stainless steel. Among them, the corrosion - resistant enhanced version adopts SUS316/SUS316L stainless steel (containing high levels of chromium, nickel, and molybdenum). This material forms a stable passive oxide layer, which endows it with excellent corrosion - resistant performance. It is particularly suitable for environments with chlorine - containing, acid, or alkaline media. Some auxiliary structures can be optionally made of corrosion - resistant engineering plastics such as PP and PVC, further enhancing the all - scenario anti - corrosion capability. -
What are the differences between SUS316 and SUS316L, and how to choose between them?
-
Is the product suitable for "strong acid/strong alkali" environments?
Application Scenarios and Specification Selection
-
What are the applicable media and environments for the JK20 Corrosion - Resistant Series?
-
hat are the pressure range and installation method options for the product?
-
Can the connection caliber be customized? What is the default interface specification?
Usage and Maintenance - Related Questions
-
How to avoid corrosion failure of the product during use?
-
What to do if the product shows signs of leakage or corrosion?
-
What is the daily maintenance cycle and key points?
Order and Customization - Related Questions
-
What customized requirements does the product support?
-
What is the product warranty period and after - sales service policy?
-
How to confirm whether the selected model is suitable for my specific working conditions?