JK20-L Bottom ported Series Corrosion-resistant pressure sensor

◆ The product can be used in non-corrosive fluid environment to SUS316

◆ Integrated R1/8 fitting with bottom wiring entry

◆ Induction and nozzle are made of stainless steel 316L

◆ Waterproof design, protection class IP65

◆ Using imported chips, higher stability

◆ LED intelligent display, easy to distinguish

◆ 3 color digital LCD intelligent display, easy to distinguish

◆ Built-in multiple units for clearer display

◆ Dual screen, display more intuitive

◆ Power saving mode can be set

◆ Key lock, prevent non-professional operation

◆ Multiple output, can separately control multiple devices

◆ Single output current up to 200mA, can control large loads

◆ Built-in over current, short circuit protection

◆ Built-in automatic fault diagnosis, fault code alarm

    Application industry

    Application industry (1)

    Pipeline pressure monitoring

    Application industry (2)

    Air leak testing

    Application industry (3)

    F.R.L (Filter, Regulator, Lubricator)

    Application industry (4)

    Gas storage cylinders

    Application industry (5)

    Adsorption verification

    Application industry (6)

    Air compressors

    Product Parameters

    Parameter Category

    Specific Parameter

    Specification

    Withstand Pressure

    High pressure

    3.0MPa (high pressure)

    Positive pressure

    2.0MPa (positive pressure)

    Compound pressure

    500kPa (compound pressure)

    Rated Pressure Range

    High pressure

    0.000~2.000MPa (high pressure)

    Positive pressure

    -0.100~1.000MPa (positive pressure)

    Compound pressure

    -100~100kPa (compound pressure)

    Protection Grade

    -

    IP65

    Set Pressure Range

    High pressure

    -0.103~2.030MPa (high pressure)

    Positive and negative pressure

    -0.103~1.030MPa (positive and negative pressure)

    Compound pressure

    -103.0~103.0KPa (positive pressure)

    Display Refresh Rate

    -

    5 times/second

    RS485 Communication Distance

    -

    Maximum connection distance ≤1200m

    Ambient Temperature

    -

    0~50℃

    Color

    -

    3 colors (white  red  orange)

    Load Current

    -

    ≤200mA

    Humidity

    Action and storage

    35~85% (no water condensation)

    Internal Pressure Drop

    -

    ≤1.0V

    Wire Specification

    -

    Oil-resistant PVC cable (0.15mm²)

    Current Consumption

    No load

    ≤40mA

    Repeatability Accuracy

    -

    ±0.3%F.S ±1digit

    Linearity

    -

    ±1%F.S

    Action Indication

    -

    OUT1

    Weight

     

    Approximately108g

    Applicable Gas

    -

    Non-corrosive fluid for SUS316 and FKM

    Minimum Unit Scale Value

    Positive pressure type kPa

    kPa(0.001), kgf/cm²(0.01), bar(0.01), psi(0.1)

    Micro and positive-negative pressure type kPa

    kPa(0.1), mmHg(1), kgf/cm²(0.001), bar(0.001), psi(0.01), inHg(0.1)

    Vibration Resistance

    Amplitude, frequency, time

    Amplitude 1.5mm, 10Hz~55Hz~10Hz per minute, 2 hours for each of X, Y, Z directions

    Storage Temperature

    Storage

    -10℃~60℃ (without water condensation and freezing)

    Temperature Characteristic

    -

    ±3%F.S, reference temperature 25℃ (0~50℃ temperature range)

    Baud Rate

    -

    9600bps, 19200bps, 38400bps, 57600bps, 115200bps

    Insulation Resistance

    Between lead and plastic shell

    ≥50MΩ (DC 500V)

    Output Voltage

    Rated voltage

    0.6V~5V ±2.5%F.S (rated voltage)

    Display Accuracy

    -

    ±1%F.S ±1digit (temperature 25±3℃)

    Withstand Voltage

    Between lead and plastic shell

    AC 1000V for 1 minute

    Impact Resistance

    -

    100m/s²(10G), 3 times for each of X, Y, Z directions

    Output Type

    -

    Open collector output (NPN or PNP, up to 2 outputs

    Interface Diameter

    -

    RC1/8”   VCR1/4”   R1/4”   M5”

    Response Time

    -

    ≤2.5ms (can be set to 25, 100, 250, 500, 1000, 1500ms)

    Design Aesthetics

    tbodytrtd valign=centerp align=centerbParameter Categorybbbptdtd valign=centerp align=centerbSpecific Parameterbbbptdtd v ( (3)
    tbodytrtd valign=centerp align=centerbParameter Categorybbbptdtd valign=centerp align=centerbSpecific Parameterbbbptdtd v ( (4)

    frequently asked questions

    • Q: Is downward piping allowed for the JK20 corrosion-resistant series?

      Yes, downward piping is permitted, but it must comply with the product’s installation specifications. The JK20’s pressure elements (bellows for low pressure, Bourdon tube for high pressure) are designed to withstand vertical downward fluid flow, but improper piping layout may cause accuracy deviations or corrosion acceleration. It is mandatory to follow the "JK20 Installation Manual" for slope and support requirements.
    • Q: What are the key prerequisites for safe downward piping?

    • Q: Can downward piping be used for vacuum or high-pressure (>40MPa) scenarios?

    • Q: What piping materials are compatible with JK20 downward piping?

    • Q: How to design downward piping to prevent medium stagnation?

    • Q: What sealing components are required for downward piping joints?

    • Q:How to avoid cavitation damage in downward piping?

    • Q:Why does the JK20 show inaccurate readings after downward piping installation?

    • Q:Can JK20 be customized for special downward piping needs?

    Make an free consultant

    Your Name*

    Phone Number

    Country

    Remarks*

    reset