| 1 |
Match the Pressure Range |
Select a sensor whose normal operating pressure is comfortably within its rated range.
Account for static pressure, pressure spikes, vacuum conditions, and possible overpressure.
|
Operating near the upper or lower limit can increase measurement uncertainty. Verify
accuracy at the actual working points, not only at room pressure.
|
Inspect for evidence of pressure shock, diaphragm damage, leakage, or zero shift after
abnormal events.
|
A correctly sized range reduces premature replacement, rejected readings, process
interruptions, and the need for protective accessories.
|
Choose the narrowest suitable range that safely covers normal operation and documented
transient conditions.
|
| 2 |
Choose the Correct Pressure Reference |
Decide whether the application requires gauge, absolute, differential, or sealed-gauge
measurement.
|
Gauge sensors may be affected by atmospheric pressure changes. Differential sensors
require both ports and should be calibrated with the intended reference configuration.
|
Keep impulse lines, ports, filters, and manifolds free from blockage, condensation,
crystallization, and trapped air where applicable.
|
The correct reference prevents control errors and avoids costly field modifications,
rewiring, or replacement caused by an unsuitable measurement principle.
|
Use differential measurement for pressure drop or level applications; use absolute
measurement when atmospheric variation must be excluded.
|
| 3 |
Verify Accuracy and Stability |
Compare total accuracy, repeatability, hysteresis, temperature effects, and long-term
stability. Do not compare only the headline accuracy figure.
|
Establish an interval from risk and drift history. A common starting point is annual
verification, then adjustment based on documented results and process criticality.
|
Trend as-found calibration data and monitor zero and span changes. Recalibrate sooner
if drift exceeds the process tolerance.
|
Higher initial accuracy can lower scrap, rework, troubleshooting time, and calibration
frequency when the process has tight measurement limits.
|
Select accuracy based on the required process tolerance, typically avoiding an
unnecessarily precise sensor that provides no operational benefit.
|
| 4 |
Check Media and Materials Compatibility |
Confirm compatibility with the measured fluid, concentration, temperature, pressure,
seals, wetted materials, and cleaning chemicals.
|
Corrosion, deposits, or chemical attack can cause apparent calibration drift. Inspect
wetted parts before accepting calibration results.
|
Use suitable isolation, flushing, diaphragm protection, or remote mounting when the
medium can clog, solidify, corrode, or damage the sensing element.
|
Compatibility failures can create leakage, contamination, unplanned shutdowns, and
frequent sensor replacement that far exceed the purchase price.
|
Base the material choice on the complete chemical and temperature profile, including
cleaning and sterilization conditions.
|
| 5 |
Evaluate Environmental and Electrical Conditions |
Review ambient temperature, humidity, vibration, shock, dust, water exposure, hazardous
areas, supply voltage, output type, and electromagnetic interference.
|
Temperature changes can alter sensor output. Calibrate or verify performance across the
expected operating temperature when temperature error is significant.
|
Inspect cable glands, connectors, grounding, enclosures, and mounting hardware. Prevent
moisture ingress and mechanical strain on the connection.
|
A properly protected installation reduces intermittent faults, nuisance alarms,
corrosion-related failures, and diagnostic labor.
|
Specify environmental protection and electrical compatibility from the installation
conditions rather than selecting them after a failure occurs.
|
| 6 |
Compare Installation and Serviceability |
Review process connections, orientation, access, wiring, isolation valves, manifolds,
replacement time, and whether the sensor can be removed safely.
|
Favor installations that allow traceable in-place checks or safe removal without
disturbing adjacent instruments and process equipment.
|
Provide isolation and venting where required. Keep spare seals, connectors, and
documented procedures available for planned service.
|
Labor, access equipment, isolation time, production loss, and recalibration can cost
more than the sensor itself.
|
Compare the complete installed cost, including fittings, wiring, commissioning,
validation, and expected replacement labor.
|
| 7 |
Calculate the Total Cost of Ownership |
Include purchase price, installation, calibration, maintenance, energy or signal
conditioning, spares, downtime, disposal, and expected service life.
|
Estimate the cost of each calibration event, including labor, reference equipment,
documentation, adjustment, and any required removal and reinstallation.
|
Use a risk-based schedule. Critical applications may need more frequent verification,
redundancy, or online diagnostics than non-critical monitoring points.
|
A useful estimate is: purchase and installation cost + scheduled service cost +
calibration cost + expected failure and downtime cost over the planned service period.
|
Select the option with the lowest justified lifecycle cost while meeting accuracy,
safety, compliance, and availability requirements.
|